SYSTEM STATUS BUTTONS
Displays critical specs of Odyssey7Q. Input voltage, Current
wattage draw of Odyssey7Q (varies with mode), current
temperature of main processor. Tapping button brings up
more detailed information including the ABOUT menu of the
Odyssey7Q.
SYSTEM STATUS
VOLTS: 12.1V (6.5~34V)
POWER: 10.0W
TEMP: +31° (<60°C)
2014 JUL 21 08:42:58
ODYSSEY7Q ABOUT
FIRMWARE: 2.10.136
SERIAL: 20-00000
WARRANTY: VOID
KEYS ACTIVATED:
BASIC FS700RAW CANONRAW
POWERED: 41 DAYS 19 HRS
RECORD: 9 DAYS 4 HRS
The Odyssey7Q has a wide internal operating temperature
window, up to 65° Celsius (149° Fahrenheit). The Odyssey7Q
uses its magnesium case to passively shed excess heat. There
are no vents or fans. Even under most harsh conditions,
the Odyssey7Q should not suer any operational issues
due to heat. However, if the internal temperature of the
Odyssey7Q rises high enough there are a series of warnings
and safeguards in place to protect the device and the recorded
files.
TEMPERATURE WARNINGS AND SAFEGUARDS
System Status Text & Warning Operational Protection
59° C Yellow text No change to operation
61° C Red text & flashing warning New recordings prevented
65° C Red text & flashing warning Current recording stopped
The Odyssey7Q has a wide range of acceptable voltage for incoming power, from 6.5 volts to
34 volts. The total wattage draw from the Odyssey7Q varies depending on the operational
mode it is set to, but is always within a very modest range from less than 8 watts to no more
than 15 watts. This allows a variety of battery options to be used with the device. While there
are file recovery parameters in place, it is never a good idea to lose power while in the midst of
recording. If the incoming voltage to the Odyssey7Q drops low enough there are a series of
warnings and safeguards in place to protect the device and the recorded files.
LOW POWER WARNINGS & SAFEGUARDS
Voltage Level System Status Text & Warning Operational Protection
6.7v Yellow text No change to operation
6.5v Red text & flashing warning New recordings prevented
6.0v Red text & flashing warning Current recording stopped
Odyssey7Q Menus